HOME › Product › Indoor LED Display › Block Series
Indoor Fixed SMD GOB LED

Block Series Indoor LED Display

P1.25 — P3.91 · 7 Models · 4 Cabinet Sizes · Front Service

The size tool for indoor walls that are not a clean rectangle. Four standard cabinets — 500×250, 750×250, 1000×250, and 1000×500 mm — all 33 mm thin and 9.8 kg. Mix widths on one wall. No custom extrusion to hit an awkward opening.
Pixel Pitch
P1.25
to P3.91 · 7 models
Models
7
SMD GOB indoor SKUs
Cabinet Depth
33
mm · aluminum die-cast
Cabinet Weight
9.8
kg · all four sizes
Cabinet Sizes
4
500 / 750 / 1000 mm
Certified & Compliant
CE
FCC
EMC
TÜV
RoHS
CB
UL
ETL
Certificate copies available on request with purchase order.
Decision Guide

Who Should Choose Block

Block is the size tool. If the wall opening is the problem — not the pixel technology — start here. If the left column is your job, stay. If the right column is your job, leave this page.

Block is the right choice for
  • ✓ Awkward openings — mix 500 / 750 / 1000 mm cabinets so the wall hits the dimension without a custom cabinet
  • ✓ Churches and halls — P2.5 to P3.91 at typical seating distance, front service on a sealed wall
  • ✓ Lobbies and receptions — P1.56 to P1.95, 33 mm depth, 9.8 kg per cabinet
  • ✓ Retail and education — GOB face, indoor IP31, walk-up viewing
  • ✓ 90° corners or dual-sided walls — rotate the cabinet; optional dual-side; stock cabinets, not corner modules
  • ✓ Flush commercial walls — front service, no 600 mm rear corridor
Consider other products for
  • ✗ Under 2 m or 24/7 control rooms — Fine Pitch / COB Pro
  • ✗ Plug-and-play 16:9 rooms — All-in-One LED TV
  • ✗ Portable single units — LED Poster
  • ✗ 500 mm curve + heavier structure — Brick Series
  • ✗ Column wrap — Flexible Series
  • ✗ Rental touring — Matrix 500
  • ✗ Outdoor — Square 1000
Overview

A Size Tool, Not a Pitch Story

Most indoor walls fail the tape measure before they fail the pixel. Block exists so you can fill 3,250 mm or 2,750 mm with stock cabinets instead of a custom box.

Block is indoor fixed SMD GOB in seven pitches from P1.25 to P3.91. Every cabinet is 33 mm deep and 9.8 kg, aluminum die-cast, IP31 front and rear. The module is 250×250 mm across the range, so a 500 mm cabinet and a 1000 mm cabinet share the same spare.

The job Block is built for: the architect gave you a wall that is not a multiple of 500 mm. You mix 500×250, 750×250, 1000×250, and 1000×500 mm on one elevation. A 3,250 mm opening is two 1000 mm cabinets plus one 750 mm and one 500 mm. Leftover: zero. No custom extrusion. No waiting on a one-off die.

Inside the cabinet the hub is cable-less — power and data through board connectors, not a harness of ribbons. Cabinets rotate 90° for portrait or landscape. Dual-side is an option for a totem or a room divider. Service is from the front: pull a module off the face. The Shenzhen Triple-Fold reception used 98 stock cabinets and Block back-mount brackets — no welded steel on site.

Built in Shenzhen by 15 in-house engineers. Founded 2013. Shipped to 55+ countries. You get a cabinet list and an EXW line-item quote within 24 hours of sending width × height.

At a Glance

  • ✓ Pixel Pitch:P1.25 – P3.91 (7 models)
  • ✓ Technology:Indoor fixed SMD GOB
  • ✓ Cabinets:500×250 / 750×250 / 1000×250 / 1000×500 × 33 mm
  • ✓ Weight:9.8 kg (all sizes)
  • ✓ Module:250×250 mm
  • ✓ Contrast / Refresh:5000:1 · 3840 / 7680 Hz
  • ✓ Brightness:600 or 800 nits by pitch
  • ✓ Hub:Cable-less · 90° rotate · dual-side option
  • ✓ Service:Front
  • ✓ Power:100–200 W/m² avg · 350 W/m² max
  • ✓ Certifications:CE, EMC, RoHS
  • ✓ Warranty: 2 years
Positioning

Baseline
Recommended Upgrade
Premium Tier
Side-by-Side

Which One Is Right for Your Project?

Give suggestions on selection, point to the alternative series (inner chain), and conclude with a 24-hour response from the engineer.

Engineering

Six Decisions That Make Block the Size Tool

What the cabinet actually does on a commercial wall — and what that means for the bid.

01 — Four Cabinet Sizes

500 / 750 / 1000×250 and 1000×500 mm — Hit the Opening With Stock

Every pitch uses the same four cabinets: 500×250×33, 750×250×33, 1000×250×33, and 1000×500×33 mm. Mix them on one elevation. A 3,250 mm wall is 1000 + 1000 + 750 + 500. A 2,750 mm wall is 1000 + 1000 + 750. Height stacks in 250 mm steps; two 250 mm cabinets sit beside one 1000×500. You do not wait on a custom die for a leftover 250 mm.

Integrator benefit: You bid a cabinet list, not a custom extrusion. Send width × height; the mix comes back in 24 hours.
02 — 33 mm / 9.8 kg

33 mm Thin, 9.8 kg — Same Number on Every Size

Depth is 33 mm across the four cabinets. Weight is 9.8 kg across the four cabinets. Aluminum die-cast, indoor IP31 front and rear. A 1000×500 cabinet and a 500×250 cabinet use the same load figure on the structural drawing. The Shenzhen Triple-Fold reception hung 98 cabinets on Block back-mount brackets — no welded steel frame on site.

Integrator benefit: One weight and one depth on the drawing. The GC does not re-price steel because you swapped a 750 for a 1000.
03 — Cable-less Hub

Cable-less Hub — Power and Data on the Board, Not in a Harness

Block cabinets use a cable-less hub: module power and data seat on board connectors. You are not dressing a bundle of ribbons behind a 33 mm cabinet. Fewer connectors means fewer loose pins after a truck ride and a faster first-light. Control is Novastar or Colorlight. Inputs: DVI, HDMI, SDI, AV, DP, VGA, YPBPR. Mains: 90–264 V AC.

Integrator benefit: First-light is a board seat, not a cable hunt in a 33 mm cavity. Service later is the same path.
04 — GOB Standard

GOB Is Standard — Not an Upgrade Line on the Quote

Glue-on-board resin covers the SMD lamps on every Block module. Churches, schools, and retail floors hit the wall with bags, mops, and fingers. GOB is still SMD — it is not COB — but it stops the common indoor failure: a dead lamp from a cleaning rag. Contrast is 5000:1. Refresh is 3840 or 7680 Hz. Grayscale is 16-bit. Viewing angle is 160° H / 160° V.

Integrator benefit: You do not upsell GOB. It is on the cabinet. The face survives a lobby, not just a locked rack room.
05 — 90° / Dual-Side

Rotate 90° or Run Dual-Side — Stock Cabinets, Not Corner Modules

The same cabinet rotates 90° so the 250 mm module grid runs landscape or portrait. Dual-side is an option when both faces of a totem or a room divider need content. 90° corners use standard cabinets — the Shenzhen Triple-Fold reception held 0.5 mm at the folds with 98 stock cabinets (70 × 1000×500 and 28 × 500×250), no custom corner modules.

Integrator benefit: You sell a fold or a two-face totem from the same SKU list. The spare kit does not grow a special corner part.
06 — Front Service

Front Service — Pull the Module Off the Face

Modules come off the front. No rear corridor. No opening finished drywall behind a lobby or a sanctuary wall. The module is 250×250 mm on every pitch, so a spare from a 500 mm cabinet seats in a 1000 mm cabinet. A technician stands in the aisle. Rear-access cabinets need about 600 mm behind the wall; most commercial interiors do not have it.

Integrator benefit: You can hang Block on a sealed wall. Service does not mean a Saturday demolition of the GC's finish.
Application Scenarios

Where Block Goes on the Wall

Churches, halls, lobbies, retail, and classrooms. Not a control-room flagship — if operators sit under 2 m, use Fine Pitch.

01 — Church / Hall
Churches and Assembly Halls

Churches and Assembly Halls

Seating 6–20 m. Specify P2.5 to P3.91. Lyrics and IMAG stay sharp without paying for unused density. Front service on a sealed sanctuary wall. Read the church LED guide.

02 — Lobby / Reception
Lobbies and Reception Walls

Lobbies and Reception Walls

Walk-up 2–5 m. Specify P1.56 or P1.95. 33 mm depth and 9.8 kg keep the back-mount light. Mix cabinet widths when the architect's opening is not a 500 mm multiple. Documented job: Shenzhen Triple-Fold, P1.953, 38.5 m².

03 — Retail
Retail and Brand Floors

Retail and Brand Floors

GOB face for a floor that gets touched. 600 or 800 nits by pitch. Front service after hours from the aisle. Dual-side option for a totem in the circulation path. 90° rotate for a portrait end-cap.

04 — Education
Lecture Halls and Classrooms

Lecture Halls and Classrooms

P2.5 to P3.91 at lecture distance; P1.95 if students sit close. Front service so the university does not open the wall during term. Same 250×250 mm spare across cabinet sizes. IP31 indoor only.

Not Sure Which Config?

Send us your room dimensions, operator-to-screen distance, and ambient light conditions (lux measurements preferred). Our engineers respond with a pitch-and-brightness recommendation within 24 hours — no charge, no commitment. Submit your project specs →

Technical Specifications

Block — 7 Models, Full Specifications

Select a pixel pitch. All seven SKUs share the four cabinet sizes, 33 mm depth, 9.8 kg, 250×250 mm module, and front service.

Cabinet Sizes
500 / 750 / 1000 mm
Depth / Weight
33 mm · 9.8 kg
Module
250×250 mm
Quote
Cabinet list in 24h
Warranty
2 years
Select pixel pitch to view specifications
SMD GOB · IP31 / IP31 · Novastar / Colorlight

Model: Block P1.25 · Module Size: 250×250 · Cabinet Resolution: 800×400 / 400×200 · Pixel Pitch: 1.25

Pixel Pitch1.25
Pixel Density640000
Brightness600
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution200×200
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution800×400 / 400×200
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront

Model: Block P1.5625 · Module Size: 250×250 · Cabinet Resolution: 640×160 / 640×320 · Pixel Pitch: 1.5625

Pixel Pitch1.5625
Pixel Density409600
Brightness600
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution160×160
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution640×160 / 640×320
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront

Model: Block P1.953 · Module Size: 250×250 · Cabinet Resolution: 512×128 / 512×256 · Pixel Pitch: 1.953

Pixel Pitch1.953
Pixel Density262144
Brightness800
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution128×128
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution512×128 / 512×256
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront

Model: Block P2.5 · Module Size: 250×250 · Cabinet Resolution: 400×100 / 400×200 · Pixel Pitch: 2.5

Pixel Pitch2.5
Pixel Density160000
Brightness800
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution100×100
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution400×100 / 400×200
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront

Model: Block P2.604 · Module Size: 250×250 · Cabinet Resolution: 384×96 / 400×200 · Pixel Pitch: 2.604

Pixel Pitch2.604
Pixel Density147456
Brightness800
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution96×96
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution384×96 / 400×200
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront

Model: Block P2.976 · Module Size: 250×250 · Cabinet Resolution: 336×84 / 336×168 · Pixel Pitch: 2.976

Pixel Pitch2.976
Pixel Density112896
Brightness800
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution84×84
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution336×84 / 336×168
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront

Model: Block P3.91 · Module Size: 250×250 · Cabinet Resolution: 256×64 / 256×128 · Pixel Pitch: 3.91

Pixel Pitch3.91
Pixel Density65536
Brightness800
Contrast Ratio5000:1
Refresh Rate3840 / 7680
Grayscale16
Viewing Angle160°H / 160°V
Module Size250×250
Module Resolution64×64
Cabinet Size500×250×33 / 750×250×33 / 1000×250×33 / 1000×500×33
Cabinet Resolution256×64 / 256×128
Cabinet Weight9.8
Cabinet MaterialAluminum die-casting
Service AccessFront
→ Request the Full Datasheet All models · brightness tier guide · power & BTU calculations · bracket CAD · calibration methodology · sent by an engineer within 24 hours
Viewing Distance

Recommended Viewing Distance by Pixel Pitch

Model Pixel Pitch Min. Viewing Distance Optimal Viewing Distance Typical Application Relative Resolution
型号 1 间距 最小视距 最佳视距 典型应用
型号 2 间距 最小视距 最佳视距 典型应用
Packaging & Delivery

What's in the Box

What arrives on the pallet. Spare modules, back-mount brackets, and the cabinet mix drawing ship with the order — not as a follow-up email.

LED Cabinets
Pre-assembled 500 / 750 / 1000 mm cabinets, SMD GOB modules seated, 33 mm aluminum die-cast.
Back-Mount Brackets
Block back-mount brackets sized to the wall. Bolts on site. No welded steel frame required — as on the Shenzhen Triple-Fold job.
Controller & Cables
Novastar or Colorlight, mapped to your pixel count. Power, Ethernet, and spare signal cables. Inputs: DVI, HDMI, SDI, AV, DP, VGA, YPBPR.
Spare Modules
250×250 mm GOB spares ship with the order. Same module seats in every cabinet size. Front-service swap from the aisle.
Cabinet Mix Drawing
Width × height packed into 500 / 750 / 1000 mm cabinets. Load sheet uses 9.8 kg per cabinet. Printed and on USB.
QC Pack
GOB module close-up on file, QC checklist, serials. Certificate copies (CE, EMC, RoHS) on request with the PO.
Installation Cases

One Documented Wall

Stock Block cabinets. A triple-fold reception. No custom corner modules, no welded steel.

Deployment Status

New Technology · Ready for Deployment

Block — Engineered, Validated, Awaiting Its First Field Installation

Is your project the first Block deployment?

Contact Kris Liang directly to chat about verification data + factory video connection.

WhatsApp Kris Liang — Discuss Block →
Downloads

Technical Assets for System Design

Ask an engineer. No registration form. Name the pitch and the wall width; the matching revision goes out by email.

PDF
Full Specification Datasheet
Block Series — All 7 Models
P1.25 through P3.91. Four cabinet sizes, power, scan, module pixels, and the 250×250 mm spare rule. CE, EMC, RoHS listed.
→ Request PDF
PDF · emailed within 24 hours
DWG
DWG Document
Block Cabinets — Mechanical Drawing
.DWG for 500×250, 750×250, 1000×250, and 1000×500 mm. Mounting holes, 33 mm depth, back-mount interface. AutoCAD 2018+.
→ Request DWG
DWG · emailed within 24 hours
PDF
Full Specification Datasheet
Width × Height → Cabinet List
Pack a wall into 500 / 750 / 1000 mm widths and 250 / 500 mm heights. Returns leftover millimetres and 9.8 kg load. Same logic as the calculator below.
→ Request PDF
PDF · emailed within 24 hours
System Design Tool

Block Wall Calculator

Enter your wall dimensions to calculate cabinet count, total resolution, and power requirements — instantly, with no signup.

Results will appear here
Cabinets (W × H)—
Total Cabinets—
Total Resolution—
Wall Area—
Max Power Draw—
Avg Power Draw—
Heat Load (BTU/hr)—
Request Formal Quote →

Results are estimates based on cabinet count rounding. Contact our engineers for a confirmed cabinet count and structural load calculation.

FAQ

Common Questions from Integrators

Block ships four standard cabinets: 500×250, 750×250, 1000×250, and 1000×500 mm, all 33 mm deep. Mix widths on one wall. A 3,250 mm opening is two 1,000 mm plus one 750 mm and one 500 mm — leftover zero. Height stacks in 250 mm steps. Send width × height; an engineer returns a cabinet list and an EXW quote within 24 hours.
Choose Block when the wall dimension is the problem: four cabinet sizes, 33 mm depth, 9.8 kg, cable-less hub, GOB standard. Choose Brick when you need a 500 mm system with curve options and a heavier 19 kg structure at 43.7 mm. Same indoor job, different geometry. Block is the size tool. Brick is the 500 mm curve-ready tool. Do not mix them on one wall without a drawing review.
Choose All-in-One when the room is a standard 16:9 conference space and you want a plug-and-play TV, not a cabinet wall. Block is modular: you specify pitch, mix cabinet sizes, hang on a back-mount, and service from the front. If the client wants a remote, a stand, and no structural drawing, send them to All-in-One LED TV. If the opening is not 16:9 or they need 90° or dual-side, stay on Block.
Switch to Fine Pitch or COB Pro when operators sit under 2 m or the wall runs 24/7 in a control room. Block is indoor SMD GOB from P1.25 to P3.91 — right for churches, halls, lobbies, retail, and classrooms at walking or seating distance. Below 2 m, SMD pixel structure becomes visible and COB is the better surface. Do not specify Block as a control-room flagship.
For a church or hall, specify P2.5 to P3.91. Seating is usually 6–20 m; those pitches stay sharp on IMAG and lyrics without unused density. For a lobby or reception at 2–5 m, specify P1.56 or P1.95. P1.25 is the close-range Block option when guests walk the wall. Send seating distance and wall width; we return a pitch plus cabinet mix in 24 hours.
Block is front service. Modules pull from the face of the wall — no rear corridor, no opening finished drywall. A technician swaps a 250×250 mm module from the aisle. Rear-access cabinets need about 600 mm behind the wall; most commercial interiors do not have it. That is why Block hangs on sealed lobby and sanctuary walls. Read the front-service vs rear-access guide if the architect already closed the cavity.
GOB (Glue on Board) is standard on every Block cabinet. A resin layer covers the SMD lamps, so the module face resists knocks, dust, and moisture better than bare SMD. Churches, schools, and retail floors hit the wall. GOB is not COB — the lamps are still SMD — but it cuts the common indoor failure: a dead lamp from a cleaning rag or a backpack. Specify GOB as included, not an upgrade.
Block draws 100–200 W/m² average and 350 W/m² maximum at 90–264 V AC. Ingress is IP31 front and rear — indoor only. Contrast is 5000:1; refresh is 3840 or 7680 Hz; viewing angle is 160° H / 160° V. Warranty is 2 years. Certifications are CE, EMC, and RoHS. An engineer sizes breakers from your cabinet count, not from a generic per-m² guess.
Yes. Block cabinets rotate 90° so the same 250 mm module grid can run landscape or portrait. Dual-side is an option when you need content on both faces of a totem or room divider. 90° corners use standard cabinets, not custom corner modules. The Shenzhen Triple-Fold reception held 0.5 mm at the folds with 98 stock cabinets. Send the fold drawing before you lock the steel.
Explore More

Factory-Direct Shenzhen 55+ Countries 2-Year Warranty UL / CE / FCC / EMC / TÜV / CB / RoHS / ISO 9001 15–20 Day Lead Time Engineering Support Included
Next Steps

Ready to Specify Block for Your Project?

Ready to Quote
Request Pricing & Availability
Tell us the pixel pitch, cabinet count, brightness tier, and preferred Hub Board architecture. We respond with a line-item quotation within 24 hours.
WhatsApp — Get Quote →
Need Full Specs
Request the Datasheet
All 7 models, four cabinet sizes, power, scan, module pixels. An engineer emails the PDF within 24 hours.
Request PDF →
Evaluating Options
Talk to an Engineer
Not sure which pitch or brightness tier fits your installation? Our engineers respond directly — no sales layer.
Contact Engineer →
Get in touch
Start your project.
We respond same day.
Send your room dimensions, pixel pitch requirements, or project brief — an engineer replies within hours.
Same-day engineer response  ·  CE · EMC· RoHS
Manufacturer
DOIT VISION
Founded
2013, Shenzhen, China
Headquarters
Shenzhen, Guangdong, China
Certifications
CE, FCC, RoHS, CB, ISO 9001
Official Website
https://www.doitvision.com/